Fujitsu Halcyon Hybrid Flex Inverter 2 to 4 Zones Mini Split Heat Pumps

[av_one_half first av_uid=’av-5lndf0′]

ASU7RLF1, 9RLF1, 12RLF1, 18RLF, 24RLF

Wall Mounted Designer Series Indoor Unit

ASU9RLS2, 12RLS2, 15RLS2

Slim Duct Indoor Unit

ARU7RLF, 9RLF, 12RLF, 18RLF, 24RLF

Compact Cassette Indoor Unit

AUU7RLF, 9RLF, 12RLF, 18RLF

Floor Mounted Indoor Unit

AGU9RLF, 12RLF, 15RLF

Outdoor Unit Model Numbers

AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ

[/av_one_half]

[av_one_half av_uid=’av-43qsb0′]

Outdoor models AOU18RLXFZ, AOU24RLXFZ and AOU36RLXFZ allow you to connect 2 to 4 indoor units, depending on the outdoor unit selected. These systems provide both heating and cooling for year-round comfort. Choose from four indoor unit styles – wall mounted, floor mounted, cassette and slim duct – to best match your decor. Create the right combinations, the right quantity, the right style indoor units, and the right capacity. It’s the right choice for your home or business.

[av_image src=’https://impressiveclimate.com/wp-content/uploads/2015/01/Multi-Zone.gif’ attachment=’3339′ attachment_size=’full’ align=’center’ animation=’left-to-right’ link=” target=” styling=” caption=” font_size=” appearance=” av_uid=’av-9fd1o’][/av_image]

[/av_one_half]

 

Fujitsu Halcyon Hybrid Flex Inverter 2-4 Zones Mini Split Heat Pumps
http://www.google-analytics.com/ga.js//

Individual Zoning
Each indoor unit can be operated independently. That is, on/off, temperature, air movement, up/down (wall mount unit only), time clock operation, can all be controlled from their own remote.

Inverter Technology
Through new, advanced technology, Inverter air conditioners are more economical to operate and quieter to run than conventional units. They can handle greater extremes in temperature, are smoother and more stable in operation, and reach the desired temperature faster than conventional air conditioners.

Inverter control
The Inverter component allows the outdoor unit to vary its speed and output to match the required capacity of the indoor unit. Thus, the Inverter model can achieve 30% more operating efficiency than conventional models and therefore, is much less expensive to run.     

Cassette Model Fits Into Standard Ceiling Tile

Hidden or Showcased Indoor Unit
Choose from either a wall mounted, floor mounted, compact cassette or slim duct unit for either a showcased or hidden look.

Stable and comfortable
The air conditioner’s output power is stabilized at the optimum setting within the range from maximum to minimum to match the load, which is affected by factors such as the room temperature and the number of people present.

Other Standard Features Include:

 

 Wall Mount Series
 Apple Catechin Filter
Ion Deodorizing Filter
Sleep Timer
24-Hour Timer
Dry Mode
Auto Louver: Up/ Down
Auto Louver: 4-way*
Auto Mode
Minimum Heat Mode
Quiet Mode
Auto Restart/Reset
Auto Changeover
Low Ambient
Power Diffuser*

*Feature of models ASU18, 24RLF only.

 

 Slim Duct 
Dry Mode
Weekly Timer
Sleep Timer*
24-Hour Timer*
Minimum Heat Mode*
Auto Mode
Quiet Mode
Auto Restart/Reset
Auto Changeover
Low Ambient
Long Piping Length
Condensate Pump
Fresh Air Intake

*Available only with optional wireless remote control.

 

 Cassette 
 Weekly Timer
Dry Mode
Auto Louver: Up/ Down
Quiet Mode
Auto Restart/Reset
Auto Changeover
Low Ambient
 Long Piping Length
Remote Temperature Sensor
High Ceiling Mode
Condensate Pump
2-Stage Turbo Fan
Fresh Air Intake**


**Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection and a field supplied duct booster capable of 60 CFM at a .2� W.C. or 90 CFM at .4� W.C. For fan curve, see installation manual.

 

 

Wall Mounted RLF1 and RLF Series
Wall Mounted Designer Series
Compact CassetteSlim Duct
Floor MountWall Mounted RLF1 and RLF Series Specifications

  SYSTEM ASU7RLF1 ASU9RLF1 ASU12RLF1 ASU18RLF ASU24RLF
  Cooling BTU/h
  Outdoor Design Temp
  Heating BTU/h
  Outdoor Design Temp
  SEER*
  HSPF *
  EER Clg/Htg*
  Power Supply (V)
7000 9000 12000 18000 24000
95/75 95/75 95/75 95/75 95/75
8100 10200 13500 20000 27000
47/43 47/43 47/43 47/43 47/43
17 17 17 17 17
9.8 9.8 9.8 9.8 9.8
9.25 9.25 9.25 9.25 9.25
208-230 208-230 208-230 208-230 208-230
  Noise Level db (A) Cooling
                             Hi
                             Med
                             Lo
  Noise Level db (A) Heating
                             Hi
                             Med
                             Lo
  Weight (lbs.)
36 37 40 43 49
32 33 36 37 42
29 29 30 33 37
36 37 40 44 48
32 33 36 37 42
29 29 31 33 37
19 19 19 31 31
Wall Mounted Designer Series Specifications
  SYSTEM 9RLS2 12RLS2 15RLS2 
  CAPACITIES:
  Cooling BTU/h 9,000 12,000 14,000
  Outdoor Design Temp
Fº  DB/WB
95/75 95/75 95/75
  Heating BTU/h 10,200 13,500 16,300
  Outdoor Design Temp
Fº  DB/WB
47/43 47/43 47/43
  Power Supply (V) 208-230 208-230 208-230
  Noise Level db (A) Cooling
Hi
Med
Lo
Quiet
36
32
28
21
37
34
31
21
41
36
33
25
  Noise Level db (A) Heating
Hi
Med
Lo
Quiet
36
32
28
21
37
34
31
21
41
36
33
25
  Weight (lbs.) 21 21 21
Compact Cassette Specifications

  SYSTEM AUU7RLF AUU9RLF AUU12RLF AUU18RLF
  Cooling BTU/h
  Outdoor Design Temp
  Heating BTU/h
  Outdoor Design Temp
  SEER*
  HSPF *
  EER Clg/Htg*
  Power Supply (V)
7000 9000 12000 18000
95/75 95/75 95/75 95/75
8,100 10,200 13,500 20,000
47/43 47/43 47/43 47/43
17 17 17 17
9.8 9.8 9.8 9.8
9.25 9.25 9.25 9.25
208-230 208-230 208-230 208-230
  Noise Level db (A) Cooling
                             Hi
                             Med
                             Lo
  Noise Level db (A) Heating
                             Hi
                             Med
                             Lo
  Weight (lbs.)
33 33 37 42
31 31 33 37
29 29 31 33
34 34 37 44
32 32 33 40
29 29 31 37
33 33 33 33

Slim Duct Specifications

  SYSTEM ARU7RLF ARU9RLF ARU12RLF ARU18RLF ARU24RLF
  Cooling BTU/h
  Outdoor Design Temp
  Heating BTU/h
  Outdoor Design Temp
  SEER*
  HSPF *
  EER Clg/Htg*
  Power Supply (V)
7000 9000 12000 18000 24000
95/75 95/75 95/75 95/75 95/75
8100 10200 13500 20000 27000
47/43 47/43 47/43 47/43 47/43
14.7 14.7 14.7 14.7 14.7
9.3 9.3 9.3 9.3 9.3
8.7 8.7 8.7 8.7 8.7
208-230 208-230 208-230 208-230 208-230
  Noise Level db (A) Cooling
                             Hi
                             Med
                             Lo
  Noise Level db (A) Heating
                             Hi
                             Med
                             Lo
  Weight (lbs.)
28 28 29 32 33
26 27 28 31 32
25 26 27 30 30
28 28 29 33 35
26 26 28 32 34
25 25 27 31 32
41 41 41 50 59

Floor Mount Specifications

  SYSTEM AGU9RLF AGU12RLF AGU15RLF
  Cooling BTU/h
  Outdoor Design Temp
  Heating BTU/h
  Outdoor Design Temp
  SEER*
  HSPF *
  EER Clg/Htg*
  Power Supply (V)
9000 12000 14200
95/75 95/75 95/75
12000 16000 18000
47/43 47/43 47/43
17.0 17.0 17.0
9.8 9.8 9.8
9.25 9.25 9.25
208-230 208-230 208-230
  Noise Level db (A) Cooling
                             Hi
                             Med
                             Lo
  Noise Level db (A) Heating
                             Hi
                             Med
                             Lo
  Weight (lbs.)
39 36 44
34 30 38
28 22 31
39 36 44
34 30 38
28 22 31
31 31 31

 

 

 

 

 

 

 

 

 

 

 

 

 

 