{"product_id":"broan-vbathw-20-40-60-timer","title":"BROAN AI Series 20-40-60 min. Timer – VBATHW (4-WIRE)","description":"\u003cp\u003e\u003cspan\u003eThe 20-40-60 Control is for installation in a bathroom, a laundry room or a workshop. This auxiliary wall control can be installed with any main control of the AI series.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eBroan-NuTone, LLC. \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel Series: \u003cstrong\u003eBroan AI Series\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel Description: \u003cstrong\u003e4-Wire \u003c\/strong\u003e\u003cstrong\u003e20-40-60 Control\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer's Part Number:\u003cstrong\u003e VBATHW \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer's OLD Part Number:\u003cstrong\u003e 41300, 41100\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatibility: \u003cstrong\u003evanEE, Venmar, Broan AI Series\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManual override boost function by pushing of switch in 20, 40, and 60 minute durations\u003c\/li\u003e\n\u003cli\u003ePowered by low-voltage source from home's HRV or ERV system\u003c\/li\u003e\n\u003cli\u003eModern design with settings behind concealed door to easily blend into the interior space\u003c\/li\u003e\n\u003cli\u003eFits in single-gang box with faceplate included\u003c\/li\u003e\n\u003cli\u003eFully compatible with AI Series HRV or ERV systems and ONE Series ERV systems\u003c\/li\u003e\n\u003cli\u003eMultiple VBATHW controls can be connected to a single HRV or ERV system\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Models \u003cstrong\u003e(vanEE, Venmar, Broan AI Series)\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eV,A,B110H65RS\u003c\/li\u003e\n\u003cli\u003eV,A,B110H65RT\u003c\/li\u003e\n\u003cli\u003eV,A,B130H65RS\u003c\/li\u003e\n\u003cli\u003eV,A,B130H65RT\u003c\/li\u003e\n\u003cli\u003eV,A,B130E65RS\u003c\/li\u003e\n\u003cli\u003eV,A,B130E65RT\u003c\/li\u003e\n\u003cli\u003eV,A,B160H65RS\u003c\/li\u003e\n\u003cli\u003eV,A,B160H65RT\u003c\/li\u003e\n\u003cli\u003eV,A,B160E65RS\u003c\/li\u003e\n\u003cli\u003eV,A,B160E65RT\u003c\/li\u003e\n\u003cli\u003eV,A,B150H75NS\u003c\/li\u003e\n\u003cli\u003eV,A,B150H75NT\u003c\/li\u003e\n\u003cli\u003eV,A,B150E75NS\u003c\/li\u003e\n\u003cli\u003eV,A,B150E75NT\u003c\/li\u003e\n\u003cli\u003eV,A,B160H75RS\u003c\/li\u003e\n\u003cli\u003eV,A,B160H75RT\u003c\/li\u003e\n\u003cli\u003eV,A,B160H80RT\u003c\/li\u003e\n\u003cli\u003eV,A,B160E75RS\u003c\/li\u003e\n\u003cli\u003eV,A,B160E75RT\u003c\/li\u003e\n\u003cli\u003eV,A,B210E75RT\u003c\/li\u003e\n\u003cli\u003eV,A,B210E75RS\u003c\/li\u003e\n\u003cli\u003eV,A,B230H75RS\u003c\/li\u003e\n\u003cli\u003eV,A,B230H75RT\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote these new\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e41300 \/ 4100 \/ VBATHW\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003etimers are not compatible with the old style\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1806110\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e03701\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003etimers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou cannot mix and match the timers on the same unit.\u003c\/p\u003e\n\u003cp\u003eThey either all must be the old style, or all must be VBATHW\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eNOTE If you have the older Venmar terminal block,  wiring is as follows:\u003c\/p\u003e\n\u003cp\u003eB \u0026gt;\u0026gt;\u0026gt; GND\u003c\/p\u003e\n\u003cp\u003eOL \u0026gt;\u0026gt;\u0026gt; OVR\u003c\/p\u003e\n\u003cp\u003eOC \u0026gt;\u0026gt;\u0026gt; 12V\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe new timers can be hooked up with 3 or 4 wires. The lighting will work differently if using only 3 wires. On the terminal block of the air exchanger, remove the wire plugged into 'I' and move it to 'B'. If there is already something plugged into 'B', you will have to splice that wire with the wire you just removed from 'I'. Once that is done, you will plug in as follow: B= GRND, OL= OVR, OC = 12V.  \u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDownloads:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"g-c g-c--md6\"\u003e\u003ca class=\"ico-docs h-textXl h-underline h-colorInherit\" href=\"https:\/\/www.broan-nutone.com\/getmedia\/2d328a78-e6a7-44a3-9003-b1d699061e06\/Installation-Guide-VBATHW.pdf?ext=.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"g-c g-c--md6\"\u003e\u003ca class=\"ico-docs h-textXl h-underline h-colorInherit\" href=\"https:\/\/www.broan-nutone.com\/getmedia\/a91b1616-4d06-449c-abfa-0c14add1aa99\/Spec_Sheet_WallControls_En_Fr.pdf?ext=.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eSpecification Sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Broan","offers":[{"title":"Default Title","offer_id":53051727446388,"sku":"VBATHW","price":54.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/1596\/0180\/files\/broan-ai-series-20-40-60-min-timer-vbathw-4-wirevbathwimpressive-climate-control-2668204.jpg?v=1786586120","url":"https:\/\/impressiveclimate.com\/products\/broan-vbathw-20-40-60-timer","provider":"Impressive Climate Control","version":"1.0","type":"link"}